Home / All / Outdoor Fiber Optic Cables / Duct Fiber Optic Cables /

FCJ factory GYTA outdoor Fiber Optic Cable

FCJ factory GYTA outdoor Fiber Optic Cable

FCJ factory GYTA outdoor Fiber Optic Cable
FCJ factory GYTA outdoor Fiber Optic CableFCJ factory GYTA outdoor Fiber Optic CableFCJ factory GYTA outdoor Fiber Optic CableFCJ factory GYTA outdoor Fiber Optic CableFCJ factory GYTA outdoor Fiber Optic Cable
CategoriesDuct Fiber Optic Cables
BrandFCJ Fiber Optic Products Manufacturer
ModelGYTA
Terms of PaymentL/C, D/A, D/P, Western Union
Download
Update TimeDec 22,2024
Detail Information

Description

The fibers, 250μm,are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire, sometimes sheathed with polyethylene (PE) for cable with high fiber count, locates in the center of core as a metallic strength member. Tubes (and fillers) are stranded around the strength member into a compact and circular cable core. An Aluminum Polyethylene Laminate (APL) is applied around the cable core, which is filled with the filling compound to protect it from water ingress. Then, the cable is completed with a PE sheath.

Characteristics

· Good mechanical and temperature performance

· High strength looes tube that is hydrolysis resistant

· Special tube filling compound ensure a critical protection of fiber

· Specially designed compact structure is good at preventing loose tubes from shrinking

· PE sheath protects cable from ultraviolet radiation

· The following measures are taken to ensure the cable watertight:

                - Steel wire used as the central strength member

                - Loose tube filling compound

                - 100% cable core filling

                 - APL moisture barrier

Standards

GYTA cable complies with Standard YD/T 901-2001as well as IEC 60794-1.

Optical Characteristics

 

 

G.652

G.655

50/125μm

62.5/125μm

Attenuation

(+20℃)

@850nm

 

 

3.0 dB/km

3.0 dB/km

@1300nm

 

 

1.0 dB/km

1.0 dB/km

@1310nm

0.36 dB/km

0.40 dB/km

 

 

@1550nm

0.22 dB/km

0.23dB/km

 

 

Bandwidth (Class A)

@850nm

 

 

500 MHz·km

200 MHz·km

@1300nm

 

 

1000 MHz·km

600 MHz·km

Numerical Aperture

 

 

0.200±0.015NA

0.275±0.015NA

Cable Cut-off Wavelength

1260nm

1480nm

 

 

 

 

 

 

Technical Parameters

Cable Type

Fiber Count

Tubes

Fillers

Cable Diameter

mm

Cable Weight kg/km

Tensile Strength

Long/Short Term N

Crush Resistance

Long/Short Term

N/100mm

Bending Radius

 

Static/Dynamic

mm

GYTA-2~6

2~6

1

4

9.7

90

600/1500

300/1000

10D/20D

GYTA-8~12

8~12

2

3

9.7

90

600/1500

300/1000

10D/20D

GYTA-14~18

14~18

3

2

9.7

90

600/1500

300/1000

10D/20D

GYTA-20~24

20~24

4

1

9.7

90

600/1500

300/1000

10D/20D

GYTA-26~30

26~30

5

0

9.7

90

600/1500

300/1000

10D/20D

GYTA-32~36

32~36

6

0

10.2

104

1000/3000

300/1000

10D/20D

GYTA-38~48

38~48

4

1

11.0

117

1000/3000

300/1000

10D/20D

GYTA-50~60

50~60

5

0

11.0

117

1000/3000

300/1000

10D/20D

GYTA-62~72

62~72

6

0

11.5

126

1000/3000

300/1000

10D/20D

GYTA-74~84

74~84

7

1

13.4

154

1000/3000

300/1000

10D/20D

GYTA-86~96

86~96

8

0

13.4

154

1000/3000

300/1000

10D/20D

GYTA-98~108

98~108

9

1

14.8

185

1000/3000

300/1000

10D/20D

GYTA-110~120

110~120

10

0

14.8

185

1000/3000

300/1000

10D/20D

GYTA-122~132

122~132

11

1

16.9

228

1000/3000

300/1000

10D/20D

GYTA-134~144

134~144

12

0

16.9

228

1000/3000

300/1000

10D/20D

GYTA-146~216

146~216

 

 

16.9

233

1000/3000

300/1000

10D/20D

Storage/Operating Temperature : -40℃ to + 70℃

 